Home >> Other Fittings >> RLY Oil Combustion Hot Air Furnace
prev
RLY Oil Combustion Hot Air Furnace
next
RLY Oil Combustion Hot Air Furnace
Description
The fuel is burnt at firebox and the high temperature is produced.
 
  • Product Details
  • Inquire Now

Principle

The fuel is burnt at firebox and the high temperature is produced. The quantity of heat will conduct to air to be heated through heat exchange device. Through heat exchange, the temperature of air is dropped to less than 250 and the air will be discharged. The air to be heated is sent to hot air furnace through distribution blow fan. After absorbed heat to the rated value, the air will be sent from the vent of hot air. When the temperature of hot air reaches the rated upper limit, the burner can stop or turn to small fire automatically. When the temperature of hot air drops to the rated low limit, the burner can burn or turn to big fire automatically.

Installation diagram

 

Applications

Industries for using the furnace For example 
Metal surface covering or coating high temperature solidification after plastic spray or paint spray 
Medicine drying the herbal medicine material of traditional Chinese medicine 
Grain processing drying the grain and starch 
Food cake baking, convenient noodle, fine dried noodle drying, transmission belt, spec baking machine 
Wood processing wood drying, fibre plate and compound plate drying 
Textile, Printing and dyeing printing drying, heat shaping, hot air widening 
Chemical products drying the chemical raw materials 
Automobile channel spec baking room.

Technical paramenters

name\spec JRF-15 JRF-20 JRF-30 JRF-40 JRF-60 JRF-80 JRF-100
diametral of interior barrel 760 760 1170 1170 1470 1670 1870
diametral of exterior barrel 1280 1280 1840 1840 2200 2460 2700
total height 3500 3500 4260 4760 4810 5110 5310
total weight of equipment 3.15T 3.65T 6.8T 7.5T 9.8T 11.7T 13.5T
diameter of hot air outlet opening 300 300 500 500 500 600 600
height of hot air outlet opening 1585 1585 1670 1670 1670 1770 1770
diameter of flue outlet opening 250 250 250 250 250 300 320
height of flue outlet opening 2050 2050 2220 2220 2220 2385 2385
specification of angle head XZD/G $578 XZD/G $810
coal consumption per hour 43kg 57kg 85kg 115kg 170kg 230kg 286kg
combustion value of coal 5000kcal/h
heat efficiency 70-75% 75-80%
suction fan of flue Y5-47-3.15C-1.5KW Y5-48-4C-2.2KW Y5-48-4C-3KW Y5-47-4C-3KW Y5-47-4C-4KW Y5-47-5C-7.5KW
  • *Subject:
  • Your Name:
  • Tel Number:
  • *Your E-Mail:
  • *Content:
    Note:HTML is not translated!